ULVAC-RIKO, Inc. today announced the release of Xe Flash TD-1, a compact and energy saving solution for measurement thermal diffusivity utilizing the xenon flash method.ULVAC-RIKO, Inc. today announced the release of Xe Flash TD-1, a compact and energy saving solution for measurement thermal diffusivity utilizing the xenon flash method.

Xenon light, with its characteristic low energy and short heat time, enables the TD-1 thermal diffusivity measuring system to measure polymer materials of μm order thickness, and other low thermal diffusivity samples such as adhesive, paint, and others. The TD-1 thermal diffusivity measurement system comes standard with its own multilayer analysis software capable of calculating thermal diffusivity of polymer film layer on top of substrates or adhesive attached in-between substrates. The TD-1 can also measure the thermal diffusivity along the thickness direction as well as in-plane direction; as such, for evaluation of materials with different thermal diffusivity in the horizontal and perpendicular directions to the molecular orientation such as liquid crystal polymers, no other addition equipment is necessary. Moreover, depending on the different properties of the sample being measure, to prevent oxidization and improve thermal distribution, the TD-1 is capable of measurement using normal atmosphere, vacuum, or other various gases.

As modern devices and electronics increase in sophistication and density, the importance of polymer materials is increasingly becoming evident. Today, polymer materials are used in a wide range of application. In general, due to their low thermal conductivity, polymer materials are easily damaged by laser irradiation when measured or analyzed. ULVAC-RIKO has developed the TD-1 thermal diffusivity measurement system specifically for the evaluation of thermo-physical properties of polymer materials such as high-function films, which is difficult to measure by existing laser based methods.


[Features]

・ Best solution for the thermal physical properties evaluation of thermal conductive polymers.

・ Multi layer normal direction analysis software included as standard.

・ Thermal diffusivity evaluation along the in-plane direction. (For anisotropic evaluation of thermal diffusivity)

・ Measurement condition includes normal atmosphere, vacuum, and other gases (For RTA type, normal atmosphere only)

・ Energy efficient. (AC 100 V, 15 A, not including PC)

・ Small foot print suitable for desktop setting. (Ca. 710mm W × Ca. 620mm D, HTV type)

・ Temperature control from room temperature to 350ºC. (HTV type)

・ Maximum of 4 samples simultaneously with multi sample holder.(HTV type, RTV type)

・ Specific heat capacity measurement by noncontact method.

[Exhibition Schedule]

We will be at the "2nd High-Function Film Technology Expo〜Film Tech Japan" at Tokyo Big Sight running from April 13~15. The TD-1 will be located at our booth located at 2-46 in the east 3 hall.

[Type & Price]

TD-1 HTV type(350ºC atmosphere, vacuum, and other gases) Domestic catalog price 12,800,000 yen.(standard set, sales tax and S&H not included)
TD-1 RTV type(room temperature atmosphere、vacuum、and other gases) Domestic catalog price 10,800,000 yen.(standard set, sales tax and S&H not included)
TD-1 RTA type(room temperature normal atmosphere type) Domestic catalog price 8,800,000 yen.(standard set, sales tax and S&H not included)

[Applications]

・ Thermal conductivity evaluation of polymer materials by measurement of thermal diffusivity and specific heat capacity.

・ Thermal diffusivity evaluation of multi layer materials・ Anisotropic thermal diffusivity evaluation in the in-plane direction.

[Applicable materials]

・ Polymer film.

・ Adhesive.・ Paint.

・ Highly-thermal conductive sheet.

・ double-stick tape.

・ Other polymer materials.

[Explanation of technical term]

1. Thermal diffusivity α (m2 s-1)

Thermal diffusivity is index parameter expressing how quick materials conduct heat. For example, in the case of metal materials, when one side is heated, the other one is quickly heated at once. However, in the case of wood building materials, when one side is heated, other side is not quickly heated. This indicates that the thermal diffusivity of metal is larger than that of wood.

2. Thermal conductivity λ (W m-1 K-1)

Thermal conductivity is index parameter expressing how large materials conduct heat. By using thermal diffusivity, thermal conductivity is shown as following equation.

λ = α C ρ

C (J kg-1 K-1):specific heat capacity ρ (kg m-3):density

[Specification]

Measurement Property Thermal diffusivity, Specific heat capacity,
* Thermal conductivity is given by calculation.
Sample size φ10 mm(circular disk sample, one dimensional measurement)
Sample thickness 25 μm to 2 mm(in the case of polyimide sample)
Measurement range Thermal diffusivity:1 × 10-7 to 1 × 10-4 m-2 s-1
Sample number 4 samples(HTV type has electric movement system.)
*In the case of the specific heat capacity measurement, one standard sample should be set except for other sample.
*In the RTA type, only one sample is set.
Temperature From room temperature to Max. 350ºC.(HTV type)
* In RTV and RTA types, measurement is performed at only room temperature.
Measurement condition Atmosphere, vacuum and various gases.
Pulse heat source Infrared red detector(light receiving element:InSb)
Sensor Infrared red detector(light receiving element:InSb)
Data operation Desk top PC(OS:Windows 7)
Software One dimensional measurement software. Multi layer analysis software
*Option Circle type sample holder.(φ12.7mm, φ15mm, φ20mm, one dimensional measurement)
Square type sample holder.(10mm□, 12.7mm□, one dimensional measurement)
Two dimensional measurement sample holder.(for in-plane evaluation)
Two dimensional measurement software.
Pirani gauge.

[Instrument setting condition]

Setting area Ca. 750mm W × Ca. 700mm D(Body、set on the disk type)
Ca. 700mm W × Ca. 800mm D(Data operation PC rack)
Body size Ca. 710mm W × Ca. 620mm D × 520mm H.(Except for a protruding object)
Body weight Ca. 40kg
Electric source Instrument operation : AC100V、15A(Plug connection attached with grounding wire)

Data operation : AC100V、10A
Cooling water Water pressure:0.15MPa  Flow:10 L/min.
(urban water or cooling water circulation system)
Atmosphere gas Inactive gas (N2、Ar、He and so on)
Supplying pressure:0.1〜0.2 MPa
Liquid nitrogen Use to cool infrared red detector.

[TD-1]

TD1H.jpg

For further information

ULVAC-RIKO, Inc. Sales department

http://www.ulvac-riko.co.jp/

TEL:+81-45-931-2285

This website use cookies to obtain and use access data to understand the convenience and usage of customers. If you agree to use cookies, click "I Accept".
[Privacy Plicy] [Cookie Policy]